Jingsan Road, Feidong Economic Development Zone, Hefei +86-17730041869 [email protected]
T-cable floor warming cable
Bring warm and comfortable feeling to people in cold season, a proven technique which is energy saving , safe and reliable. Applications: under tile, marble, laminated floor, wood etc.
Feature
Twin conductor cable
Durable construction
Emit zero EMF (Electro-magnetic Fields)
Safety approved for wet location
Flexible and easy installation
Single point connection
Technical Data
Cable construction: Twin conductor
Rated voltage: 120V, 240V
Power output: 10.3W/m (3.14W/ft)
Cable length: 11.61m (38ft) to 232.25m (762ft)
Cable diameter: 3.2mm-4.5mm (1/8"-1/6")
Conductor insulation: Fluoropolymer
Jacket: PVC/Fluoropolymer
Resistance tolerance: -5%/+10%
Max. ambient temperature: 85°F (30°C)
Min. installation temperature: 40°F (5°C)
Cold lead: 2 wire 16/14AWG + ground braid, 8ft (2.5m) length
120V |
Heating cable length |
Length/m |
Power Output/W |
Resistance/Ω -5 %/+10% |
Current/ Amps |
|||
Part Number |
m |
ft |
10Wf² |
12W/ft² |
15W/ft² |
|||
T-cable1-120 |
11.61 |
38 |
12 |
10 |
8 |
120 |
120.00 |
1 |
Tcable1-180 |
17.42 |
57 |
18 |
15 |
12 |
180 |
80.00 |
1.5 |
T-cable1-240 |
23.23 |
76 |
24 |
20 |
16 |
240 |
60.00 |
2 |
T-cable1-300 |
29.03 |
95 |
30 |
25 |
20 |
300 |
48.00 |
2.5 |
T-cable1-360 |
34.84 |
114 |
36 |
30 |
24 |
360 |
40.00 |
3 |
T-cable1-420 |
40.64 |
133 |
42 |
35 |
28 |
420 |
34.29 |
3.5 |
T-cable1-480 |
46.45 |
152 |
48 |
40 |
32 |
480 |
30.00 |
4 |
T-cable1-540 |
52.26 |
171 |
54 |
45 |
36 |
540 |
26.67 |
4.5 |
T-cable1-600 |
58.06 |
190 |
60 |
50 |
40 |
600 |
24.00 |
5 |
T-cable1-720 |
69.68 |
229 |
72 |
60 |
48 |
720 |
20.00 |
6 |
T-cable1-840 |
81.29 |
267 |
84 |
70 |
56 |
840 |
17.14 |
7 |
T-cable1-960 |
92.90 |
305 |
96 |
80 |
64 |
960 |
15.00 |
8 |
T-cable1-1080 |
104.51 |
343 |
108 |
90 |
72 |
1080 |
13.33 |
9 |
T-cable1-1200 |
116.13 |
381 |
120 |
100 |
80 |
1200 |
12.00 |
10 |
T-cable1-1440 |
139.35 |
457 |
144 |
120 |
96 |
1440 |
10.00 |
12 |
240V |
Heating cable length |
Length/m |
Power Output/W |
Resistance/Ω -5 %/+10% |
Current/ Amps |
|||
Part Number |
m |
ft |
10Wf² |
12W/ft² |
15W/ft² |
|||
T-cable2-180 |
17.42 |
57 |
18 |
15 |
12 |
180 |
320.00 |
0.75 |
T-cable2-240 |
23.23 |
76 |
24 |
20 |
16 |
240 |
240.00 |
1 |
T-cable2-300 |
29.03 |
95 |
30 |
25 |
20 |
300 |
192.00 |
1.25 |
T-cable2-360 |
34.84 |
114 |
36 |
30 |
24 |
360 |
160.00 |
1.5 |
T-cable2-420 |
40.64 |
133 |
42 |
35 |
28 |
420 |
137.14 |
1.75 |
T-cable2-480 |
46.45 |
152 |
48 |
40 |
32 |
480 |
120.00 |
2 |
T-cable2-540 |
52.26 |
171 |
54 |
45 |
36 |
540 |
106.67 |
2.25 |
T-cable2-600 |
58.06 |
190 |
60 |
50 |
40 |
600 |
96.00 |
2.5 |
T-cable2-720 |
69.68 |
229 |
72 |
60 |
48 |
720 |
80.00 |
3 |
T-cable2-840 |
81.29 |
267 |
84 |
70 |
56 |
840 |
68.57 |
3.5 |
Tcable2-960 |
92.90 |
305 |
96 |
80 |
64 |
960 |
60.00 |
4 |
T-cable2-1080 |
104.51 |
343 |
108 |
90 |
72 |
1080 |
53.33 |
4.5 |
T-cable2-1200 |
116.13 |
381 |
120 |
100 |
80 |
1200 |
48.00 |
5 |
T-cable2-1320 |
127.74 |
419 |
132 |
110 |
88 |
1320 |
43.64 |
5.5 |
T-cable2-1440 |
139.35 |
457 |
144 |
120 |
96 |
1440 |
40.00 |
6 |
T-cable2-1680 |
162.58 |
533 |
168 |
140 |
112 |
1680 |
34.29 |
7 |
T-cable2-1920 |
185.80 |
609 |
192 |
160 |
128 |
1920 |
30.00 |
8 |
T-cable2-2160 |
209.03 |
686 |
216 |
180 |
144 |
2160 |
26.67 |
9 |
T-cable2-2400 |
232.25 |
762 |
240 |
200 |
160 |
2400 |
24.00 |
10 |